Filter Results By:

Products

Applications

Manufacturers

Current Transformers

transfers accurately proportional levels of current to multiple circuits.


Showing results: 241 - 255 of 340 items found.

  • Open Loop Current Sensor

    C03 30A - Luksens Technology GmbH

    The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.

  • Digital Electrical Network Analyzer

    1826 NA - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.

  • Three Phase Power Calibrators And Tester Of Power Engineering Devices

    C300B - Calmet Smart Calibration Devices

    Three phase, class 0.02 and 0.05 power quality calibrator up to 120A (360A) and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.

  • Digital LOOP/PSC/EARTH Tester

    1824 LP - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.

  • Transformer Turns Ratio Meter

    TTRM 101 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.

  • Transformer Test Equipment

    IBEKO Power AB

    DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.

  • Compact Automatic Voltage Regulating Relay With Built- In TPI

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Compact Automatic Voltage Regulating Relays

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Automatic Voltage Regulating Relay- Standard Model

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Tap Changer Analyzers & Winding Ohmmeters

    IBEKO Power AB

    Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints

  • Computer Control 6-Phase Relay Protection Tester

    GDJB-PC6 - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1.This tester with standard 6 phase voltage, 6 phase current output,2.Voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A.3.Digital Signal Processor Microcomputer.4.Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments.

  • ESU Analyzer

    ESU-2050 - BC Group International Inc.

    The BC Biomedical ESU-2050 ESU Analyzer is the first instrument of its kind on the market. Designed through extensive collaboration with several of the world's leading electrosurgery generator manufacturers. It is the only ESU Analyzer on today's market with a 1% reading level of accuracy. Calibration quality analyzer; uses external precision non-inductive test loads and wide band current transformer.

  • Open Loop Current Sensor

    C03 50A - Luksens Technology GmbH

    The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in systems for industry and commerce as well as in communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.

  • Rotary Scale Clamp Meter

    ST-375 - Standard Electric Works Co., Ltd

    ● Designed for measuring AC current, AC voltage resistance and DC voltage .● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.

  • Primary Test Equipment

    LET-1000-RD - EUROSMC, S.A.

    It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.

Get Help